Uncooled PbSe Photoconductive Detector     


The LD-PD PbSe Series consists of high-sensitivity photoconductive detectors designed for the mid-infrared (MIR) spectral range. These detectors are optimized for gas analysis, flame detection, and environmental monitoring, offering a cost-effective solution with high stability.



Product model


Name Model Price
5x5mm Uncooled PbSe Photoconductive Detector   [PDF]  [RFQ]

LP-58TO8
[Please inquire]
3x3mm Uncooled PbSe Photoconductive Detector   [PDF]  [RFQ]

LP-35TO5
[Please inquire]
2x2mm Uncooled PbSe Photoconductive Detector   [PDF]  [RFQ]

LP-25TO5
[Please inquire]
1x1mm Uncooled PbSe Photoconductive Detector   [PDF]  [RFQ]

LP-15TO5
[Please inquire]

Parameter


Features

● Spectral Range: Highly sensitive from 1.0 μm to 5.0 μm, with peak response typically around 3.8 μm to 4.2 μm.

● Operating Principle: Photoconductive mode with negative bias capability.

● Packaging: Standard TO-46 / TO-5 headers with a gold-plated Kovar finish for superior thermal management.

● Durability: Hermetically sealed with an optical window to ensure long-term reliability in harsh environments.

Specifications

Parameter

Symbol

Value    (Typical)

Unit

Active Area Size

A

2X2(Customizable)

mm

Peak Wavelength

λ

3.8   – 4.4

μm

Peak Detectivity

D*

1X1010

cm*Hz/w

Responsivity

Rv

≥1X105

V/W

Dark Resistance

Rd

0.2   – 2.0

Time Constant

Τ.

50

μs


Typical Amplified Circuit

unCooled PbSe Photoconductive Detector1.png


Uncooled PbSe Detector

PN#

Response Range

Activearea

Package

Response   Time(us)

Peak (μm)

Peak Response(V/W)

Peak Normalized Detectivity (jones)*

Dark Resistance

(MQ   )

LP-15TO5

1-5um

1×1

TO-5

-10

3.85

200-40000

-1.5×101°

0.1-1

LP-25TO5

1-5um

2×2

TO-5

-10

3.85

500-10000

-8×10°

0.1-1

LP-35TO5

1-5um

3×3

TO-5

-10

3.85

2500-5000

-5×10°

0.1-1

LP-58TO8

1~5um

5×5

TO-8

~10

3.85

800-1600

~2.5×10°

0.1-1

Measured   Test Conditions:Radiation Source: 500K Blackbody,Chopping Frequency: 1000 Hz,Bias   Voltage : 50 V,Load Resistance: Matched to Dark Resistance ,Ambient   Temperature: 298 K (25°C)

1Jones = 1cm*√Hz/w

Package Size

Package with TEC--TO5

unCooled PbSe Photoconductive Detector2.png


Package with TEC--TO8

unCooled PbSe Photoconductive Detector3.png










Application

● Gas Sensing: NDIR (Non-Dispersive Infrared) detection for CO2, CH4, and NO.

● Industrial Safety: Flame and spark detection.

 Medical: Capnography and anesthesia gas monitoring.

● Environmental: Moisture and hydrocarbon analysis.

By using this website and services, you agree to our use of cookies. Cookies enable us to better provide member services and record your browsing records in a short time. OK Learn more
close[X]
Your shopping cart
Model Quantity Price Subtotal
Total price:USD:
View shopping cart Settlement
︿ TOP
提示