LP-6362D is a high-resolution, large-dynamic, high-speed, high-performance optical spectrum analyzer. It is perfect for testing 600 nm to 1700 nm optical systems, such as DWDM and optical amplifiers; It can also be used for optical active and passive device testing, such as LED, FP-LD, DFB-LD, optical transceivers and optical fibers and fiber gratings and other optical devices.
Name | Model | Description | Parameter | Price |
---|
● 20 pm minimum spectrum resolution
● 600 nm to 1700 nm spectrum scanning range
● 76dB large dynamic range
● 90dBm sensoring sensitivity
● Support spatial light input
● Built-in light source output configuration
● Powerful spectrum data analysis function for multiple applications
● 12.1-inch touch screen
Items | Specifications | ||
Model | LP-6362D | ||
Wavelength range *1 | 600 to 1700 nm | ||
Span *1 | 0.1 nm to 1100 nm (Full span), and 0 nm | ||
Wavelength accuracy *1, *2, *5 | ±0.02 nm (1520nm to 1620nm) ±0.04 nm (1450nm to 1520nm) ±0.10 nm (full span) | ||
Wavelength linearity *1, *2, *5 |
±0.01nm(1520~1580nm) | ||
Wavelength repeatability *1, *2 | ±0.005nm(2 minutes) | ||
Wavelength resolution setting *1, *2 | 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2 nm | ||
Wavelength resolution bandwidth accuracy *1, *2 | ±5% (1450 to 1620 nm, Resolution setting: ≥ 0.1 nm, after performing the Resolution Calibration function, at the wavelength of resolution calibration) | ||
Min. sampling resolution *1 | 0.001 nm | ||
Number of sampling | 101 to 50001, AUTO | ||
Level sensitivity setting | TRAD mode | NORMAL, MID, HIGH1, HIGH2 and HIGH3 | |
SMSR mode | MID/SMSR, HIGH1/SMSR | ||
High dynamic mode | SWITCH (Sensitivity: MID, HIGH1-3) | ||
Level sensitivity *2, *3, *4, | −9-90 dBm (1300 to 1620nm) -85 dBm (1000 to 1300nm) -60 dBm (600 to 1000nm) (Sensitivity: HIGH3) | ||
Maximum input power *2, *3 | +20 dBm (per channe, full wavelength band) | ||
Maximum safe input power *2, *3 | +25 dBm (Total input power) | ||
Level accuracy *2, *3, *4, *6 | ±0.4 dB (1310/1550nm, input power: -20dBm, sensitivity: MID) | ||
Level linearity *2, *3 | ±0.05 dB (Input level: −50 to +10 dBm, Sensitivity: HIGH1-3) | ||
Level flatness *2, *3 | ±0.1 dB (1520 to 1580 nm), ±0.2 dB (1450 to 1520 nm, 1580 to 1620 nm) | ||
Polarization dependence *2, *3, | ±0.05 dB (1550/1600 nm), ±0.08 dB (1310 nm) | ||
Dynamic range *1, *2, | Resolution: 0.02 nm | 55 dB (Peak ±0.2 nm), 37 dB (Peak ±0.1 nm) | 58 dB (Peak ±0.2 nm, 60 dB typ.), 45 dB (Peak ±0.1 nm, 50 dB typ.) |
Resolution: 0.05 nm | 73 dB (Peak ±1.0 nm), 62 dB (Peak ±0.4 nm), 45 dB (Peak ±0.2 nm) | 73 dB (Peak ±1.0 nm, 78 dB typ.), 64 dB (Peak ±0.4 nm, 70 dB typ.), 50 dB (Peak ±0.2 nm, 55 dB typ.) | |
Resolution: 0.1 nm | 57 dB (Peak ±0.4 nm), 40 dB (Peak ±0.2 nm) | 60 dB (Peak ±0.4 nm, 67 dB typ.), 45 dB (Peak ±0.2 nm, 50 dB typ.) | |
Stray-light suppression ratio | 76dB | ||
Optical return loss *11 | 35 dB typ. (with angled-PC connector) | ||
Applicable fiber | SM (9.5/125), MM (GI 50/125, GI 62.5/125, Large core: up to 200 µm) | ||
Optical connector | Optical input: Connector type FC or SC | ||
Built-in calibration light source *5 | Wavelength reference source (For optical alignment and wavelength calibration) | ||
Sweep time | NORM_AUTO: 0.2 s, NORMAL: 1 s, MID: 2 s, HIGH1: 5 s | ||
Warm-up time | Minimum 1 hour (After warming up, optical alignment adjustments required.) | ||
Displaying | 12.1 inch touch screen | ||
Storage | 128GB | ||
Working Conditions Working Temperature | 0ºC to 40ºC | ||
Humidity | ≤80% | ||
Performance guarantee temperature | 18ºC to 28ºC | ||
Dimensions Width × Height × Depth | 426mm × 221mm × 450mm | ||
Weight | 19kg | ||
Power Supply | 100~240VAC,50\60Hz | ||
Maximum Power Consumption | 100W |
*1: Horizontal scale: Wavelength display mode.
*2: With 9.5/125 µm single mode fiber with a PC type connector, after 1 hour of warm-up, after optical alignment with built-in reference light source or a single longitudinal mode laser (wavelength 1520 to 1560 nm, peak level ≥ −20 dBm, level stability ≤ 0.1 dBpp, and wavelength stability ≤ ±0.01 nm).
*3: Vertical scale: Absolute power display mode, resolution setting: ≥ 0.05 nm, resolution correction: OFF.
*4: With 9.5/125 µm single mode fiber (B1.1 type defined on IEC60793-2, PC polished, mode field diameter: 9.5 µm, NA: 0.104 to 0.107).
*5: Optical Output Options Standard C-band DFB calibration light source
DFB/FP light source (standard 1550nm, other wavelengths are optional)
SLED light source (band range optional),
SLED+C2H2 light source
Other light source type accessories can be customized
Back Panel Details:
● Spectrum parameter test and analysis for optical ICs, FP-LD, DFB-LD, optical transceiver modules, optoelectronic systems and so on.