Miniature Opto-Mechanical Switch


Wavelength range 1525 to 1610 nm,Insertion loss <0.5 dB (0.3 dB typical),Optical input power <500 mW,Switching time <4 ms (2.5 ms typical)

Part Number  :  MOMEX-11-L-1-1-0-0
Unit Price  :  USD [Please inquire]
Lead time  :   [Please inquire]
Inventory quantity   :   [Please inquire]
Email UsRequest for Quotation

The Miniature Opto-Mechanical Switch is a compact, high-reliability optical switching solution designed for fiber-optic communication systems. Featuring low insertion loss, high isolation, fast switching speed, and excellent repeatability, it ensures stable optical signal routing. With 1×1, 1×2, and 2×2 bypass configurations, latching and non-latching options, and a compact PCB-mountable design, it provides reliable performance for optical network protection, monitoring, and equipment integration.

Parameters

Specification

Wavelength range

1290 to 1330 nm and/or 1525 to 1610 nm

Insertion loss1,2

1x1, 1x2 (2x1)

2x2 (bypass)

<0.5 dB (0.3 dB typical)

<0.6 dB (0.4 dB typical)

Polarization dependent loss

<0.07 dB (0.03 dB typical)

Crosstalk

>55 dB (65 dB typical)

Return loss1

>50 dB (55 dB typical)

Optical input power

<500 mW

Repeatability

±0.02 dB (cycle to cycle)

Switching time3

<4 ms (2.5 ms typical)

Switching voltage

5 ±10% V DC

Maximum switching current

Latching

Non-latching

32 mA

46 mA

Switch lifetime4

10 million cycles

Cycle frequency

<10 Hz

Nominal dimensions (L x W x H)

17.3 x 10.4 x 8.2 mm

Operating temperature

0 to 70°C or –5 to 80°C short term5

Humidity

<85% RH, or <90% RH short term5

Storage temperature

–40 to 85°C

Qualification

Telcordia GR-1221-CORE and GR-1073-CORE

Note:

1. Specified without connectors.

2. Add an additional 0.3 dB for operation over the specified wavelength range, operating temperature range, and all states of polarization.

3. The elapsed time between power application and achievement of 90% of steady state value of the new switch.

4. One switch cycle is defined as one set pulse followed by a reset pulse.

5. Short term is defined as less than 96 consecutive hours and less than a total of  15 days over a 1-year period.


Download