LD-PD's Polarization Maintaining FBT or Filter Coupler PMTC Series Products, are used to divide input polarization maintaining fiber into two outputs according to the established spectral ratio. It is widely used in the fields of fiber laser, fiber amplifier, fiber communication and fiber sensing, with compact configuration, low insertion loss, low polarization related loss and high stability.
Name | Model | Description | Parameter | Price |
---|
● High Extinction Ratio
● Low Insertion Loss
● High Return Loss
● High Power Handling Capability
Parameters | Unit | Values | |
Port Type | 1X2 | 2X2 | |
Center Wavelength | nm | 1030 or 1064 | |
Operating Wavelength Range | nm | ±30 | |
Max. Excess Loss | dB | 0.8 | 1.2 |
Max. Uniformity (only for 50/50) | dB | 0.6 | 0.8 |
Tap Ratio (Port 2/4) | % | 1±0.2, 2±0.4, 5± 1.0, 10 & 50 | |
Min. Return Loss | dB | 50 | |
Min. Extinction Ratio (only for F type) | dB | 22 | 22 |
Min. Extinction Ratio (only for B type) | dB | 20 | 18 |
Max. Optical Handling Power (Proper SOP) | - | Pulse W idth: ps,fs; Pulse Energy: nJ; Peak Power: 0.5KW , 1KW , 10KW ,20KW and so on.(Only for Splitter) | |
Max. Tensile Load | N | 5 | |
Fiber Type | PM Panda Fiber On Input&Output, PM Panda Fiber or Hi 1060 On Tap or Specify | ||
Operating Temperature | °C | -5 to +70 | |
Storage Temperature | °C | -40 to +85 |
*Above specifications are for devices without the connectors.
*For devices with connectors, IL will be 0.5dB higher, RL will be 5dB lower, ER will be 2dB lower and optical power is only 1000mW (CW). *The PM fiber and the connector key are aligned to the slow axis. And for F type, fast axis is blocked.
*The material must be RoHS compliant
● Ultra-Fast Fiber Lasers
● Telecommunications
● Optical Amplifier
● Fiber Lasers
● Testing Systems
HPMFC-UF-①①-②-③③-④-⑤⑤-⑥⑥⑥⑥-⑦⑦⑦⑦-⑧-⑨-⑩
①①: Wavelength
03 - 1030nm
06 - 1064nm
SS - Specify
②: Port 1 - 1x2
2 - 2x2
③③: Coupling Ratio
01 - 1/99
02 - 2/98
04 - 4/96
05 - 5/95
10 - 10/90
20 - 20/80
50 - 50/50
SS - Specify
④: Axis Alignment
F - Fast Axis Blocked
B - Both Axis Working
⑤⑤: Handling Power
01 - 1W
SS - Specify
⑥⑥⑥⑥: Connector Type on Port 1, 2, 3 & 4
1 - FC/UPC
2 - FC/APC
3 - SC/UPC
4 - SC/APC
N - None S - Specify
⑦⑦⑦⑦: Fiber Jacket on Port 1, 2, 3 & 4
B - Bare Fiber
L - 900um Loose Tube
S - Specify
⑧: Fiber Type on Input&Output
1 - PM 980
*Refer to the attachment for other options.
⑨: Fiber Type on Tap
1 - PM 980
*Refer to the attachment for other options.
⑩: Fiber Length
0.8 - 0.8m
S - Specify